Serial Device Communications

Installation, configuration and troubleshooting

Skilled Engineers

Serial Device Communications

KellyGraham specialise in installation, configuration and troubleshooting of all types of serial device hardware connected over an RS485 2 wire network. This is the most common arrangement found on solar farm installations in the UK. We can help diagnose issues with MODbus and CANbus equipment installed on your site using specialist hardware and software including mbpoll and modpoll to test communication at serial level or via a gateway.

Serial Gateway Install

Serial Gateways

Field device level equipment, for example, string combiner boxes, pyranometers, temperature sensors and weather stations will most commonly be connected over an RS485 network, 2/3 wire arrangement back to a central hub/serial gateway. The gateway will then convert the serial data to be able to travel back to the main comms equipment via the ethernet standard. The most common serial protocols used are CANbus and MODbus. Configuration of serial device equipment and its associated gateway is crucial for data exchange to take place, these devices are not plug & play.

We can help with all makes and models of serial hardware installation and configuration and ensure you have configuration backups and documentation to ensure a quick turnaround to minimise downtime of failed equipment.

Serial_Gateway_Image_5

Troubleshooting

Serial line bus faults

We have had many years troubleshooting serial line bus faults and issues. Common issues include incorrectly set or missing terminating resistors, use of drop lines, crossed over cabling, breaks and the use of incorrect interfaces to name a few.

Serial-Gateway-7-RS485-Busline-Troubleshooting
Serial-Gateway-6-RS485-Busline-Troubleshooting
Loading...
Adexa

Secure Device Management

Read More
CCTV

CCTV

Read More
Solor Farm Router Installs 15

Network Device Communications

Read More
Kelly Graham Solar Farm Engineer

Training

Read More
Kelly Graham Solar Farm Engineer

Site Surveys

Read More
Solar Farm Serial Gateway Installation

Troubleshooting

Read More

Share this:

  • Click to share on Facebook (Opens in new window) Facebook
  • Click to share on X (Opens in new window) X

Keep In Touch

Twitter Facebook-f Instagram Linkedin

Navigation

  • Home
  • About
  • Contact

Services

  • Operational & Maintenance
  • Remote Router Install / Upgrade
  • Site Surveys
  • Data Acquisition System
  • Training
solar farm data communications

Company No. 11325565
VAT: 293564960

We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept All”, you consent to the use of ALL the cookies. However, you may visit "Cookie Settings" to provide a controlled consent.
Cookie SettingsAccept All
Manage consent

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
CookieDurationDescription
cookielawinfo-checkbox-analytics11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional11 monthsThe cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance11 monthsThis cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy11 monthsThe cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytics
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
Others
Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet.
SAVE & ACCEPT